CDS Maintenance Summary: Tuesday 12th August 2025

WP12746 h1omc0 Low Noise ADC Autocal Test

EJ, Jonathan, Dave:

For a first test we restarted h1iopomc0 three times to run an autocal on the low-noise ADC -- each time the autocal Failed. Next test will be to power cycle existing card leading to possible replacement.

WP12755 TW1 Raw Minute Trend Offload

Dave:

h1daqtw1 was configured to write it raw minutes into a new local directory to isolate the last 6 months of data from the running system. The NDS service on h1daqnds1 was restarted to serve these data from this location while the file transfer progresses.

Restarts

Tue12Aug2025
LOC TIME HOSTNAME     MODEL/REBOOT
09:06:26 h1omc0       h1iopomc0   <<< three ADC AUTOCAL tests
09:08:12 h1omc0       h1iopomc0   
09:08:58 h1omc0       h1iopomc0   
09:09:12 h1omc0       h1omc       <<< start user models
09:09:26 h1omc0       h1omcpi     
11:51:19 h1daqnds1    [DAQ] <<< reconfigure for TW1 offload
 

Comments related to this report
david.barker@LIGO.ORG - 07:38, Wednesday 13 August 2025 (86333)

TW1 offload status as of 07:30 Wed: 70% complete. ETA 15:15 this afternoon.