Displaying report 1-1 of 1.
Reports until 09:09, Wednesday 13 August 2025
H1 CAL
oli.patane@LIGO.ORG - posted 09:09, Wednesday 13 August 2025 (86337)
Calibration Measurement August 13, 2025 15:30 UTC

At the time of starting these measurements, we had only been Locked for 1 hour (1hr10min since MAX_POWER), so we were not fully thermalized
CALIBRATION_MONITOR screen and pydarm report are attached

Broadband
2025-08-13 15:31:30 - 15:37:02 UTC
/ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20250813T153151Z.xml

Simulines
2025-08-13 15:38:19 - 16:01:22 UTC
/ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20250813T153820Z.hdf5
/ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20250813T153820Z.hdf5
/ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20250813T153820Z.hdf5
/ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20250813T153820Z.hdf5
/ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20250813T153820Z.hdf5

Images attached to this report
Non-image files attached to this report
Displaying report 1-1 of 1.