Reports until 17:19, Tuesday 19 November 2013
H1 SUS
arnaud.pele@LIGO.ORG - posted 17:19, Tuesday 19 November 2013 - last comment - 13:10, Wednesday 20 November 2013(8635)
ITMX L1 osems

The osem signals of ITMX L1 are zeros right now. We should take a look at it tomorrow.

Comments related to this report
arnaud.pele@LIGO.ORG - 12:55, Wednesday 20 November 2013 (8643)

Filiberto changed the satellite box and the signals are now alive.

filiberto.clara@LIGO.ORG - 13:10, Wednesday 20 November 2013 (8645)
Per Arnaud's alog, looked at electronics for L1 osems. Found UIM Coil driver unit powered down. Powered unit on, but later found that the unit rocker switch breaker tripped. Continued troubleshooting and found UK satellite unit S1000283 to be missing +14V rail. Replaced unit with new satellite S1100132 to allow for check out/testing of SUS.