Displaying report 1-1 of 1.
Reports until 10:08, Thursday 14 August 2025
H1 SQZ
camilla.compton@LIGO.ORG - posted 10:08, Thursday 14 August 2025 - last comment - 13:03, Thursday 14 August 2025(86361)
Mid SQZ Data for 5kHz HOM Spacing with ZM4 Yaw alignment changes
Sheila, Camilla
 
We saved  H1:OMC-DCPD_524K_A2_IN1 data with the PD sum after Sheila changed the matrix as in 85937. DTT saved as /ligo/home/camilla.compton/Documents/sqz/templates/dtt/20250814higher_order_modes.xml screenshot attached.
Interestingly we could reduce the size of the 5kHz modes by changing ZM4 YAW alignment, at the nominal alignment and the alignment that reduced the 5kHz modes most, we also took mean sqz data, the nominal alignment had a slightly better mean SQZ.
 
Starting angle is (-)133, took SQZ_ANG SERVO to DOWN. After each step of ZM, we changed SQZ angle to get level back to 4dB ASQZ, as our 5kHz modes look clearest here.
To get mean sqz, pause SQZ_MANAGER, SQZ_LO_LR to DOWN and ADF off. Should have misaligned the FC but we didn't.
 
Type Time (UTC) Angle DTT Ref Notes
SQZ 15:54:00 - 15:59:00 (-)133 ref 0 While taking CAL measurements
FDS Mid - SQZ 16:01:30 - 16:04:00 (-)105 ref 1  
FDS Mid SQZ, -50urad pit +3deg 16:07:30 - 16:09:30 (-)109 ref 2  
FDS Mid - SQZ 16:10:30- 16:12:30 (-)111 ref 3 Redid at 4dB ASQZ
FDS Mid SQZ, -50urad yaw 16:14:30 - 16:16:30 (-)114 ref 4  
FDS Mid SQZ, +50urad yaw 16:17:45 - 16:19:45 (-)109 ref 5  
FDS Mid SQZ, +100urad yaw 16:21:30 - 16:23:30 (-)106 ref 6  
FDS Mean SQZ, +100urad yaw 16:26:00 - 16:28:00 N/A ref 7  
FDS Mean SQZ, 16:29:00 - 16:31:00 N/A ref 8  
No SQZ
16:37:00 - 16:57:00
N/A
ref 9
took 1500 avg (~10mins)
 
Took above data at NLG of 16.4, checked the NLG 76542, it's a lot better since we adjusted the pump alignment on Tuesday 86323. Then increased NLG to 37 to see if this will improve SQZ.
OPO Setpoint Amplified Max Amplified Min UnAmp Dark NLG Note
80 0.1121155 0.001849 0.0068192 -1.16e-5 16.4 Without Optimizing Temp
90 0.257827 0.001813     37.7  
Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 13:03, Thursday 14 August 2025 (86363)
Sheila, Elenna, Camilla
 
Tested if SQZ was any better with the higher NLG, see attached, it wasn't although we did have good ASQZ of 19dB. We will revert OPO setpoint to 80uW
 
Type Time (UTC) Angle DTT Ref SQZ
No SQZ
16:37:00 - 16:57:00
N/A
ref 0
 
ASQZ NLG 37 17:43:30-17:46:30 (-)81 ref 1, 10 19dB
SQZ NLG 37 17:51:00-17:54:00 (-)141 ref 2, 11 -4.5dB

 Took more 5kHz/10kHz data with the NLG at 37 (effects of HOM easier to see). DTT saved as /ligo/home/camilla.compton/Documents/sqz/templates/dtt/20250814higher_order_modes.xml

In the first set of data, Elenna added an offset to DHARD, we didn't see a change at 5kHz but there was a change at 10kHz that was debatably repeatable.
In the second set of data, Sheila added an offset to SRCL1, we saw a big change at 5kHz but no change at 10kHz, see attached at 5kHz and 10kHz.
 
Type Time (UTC) Angle DTT Ref Notes
No SQZ
16:37:00 - 16:57:00
N/A
ref 0
 
ASQZ NLG 37 17:43:30-17:46:30 (-)81 ref 1, 10  
SQZ NLG 37 17:51:00-17:54:00 (-)141 ref 2, 11  
Mid SQZ 18:00:30 - 18:02:30 (-)118 ref 12  
Mid SQZ +4cts DHARD PIT 18:06:30 - 18:08:30 (-)118 ref 13 Difference only at 10k? Repeat
Mid SQZ 18:09:30 - 18:11:30 (-)118 ref 14  
Mid SQZ +4cts DHARD PIT 18:12:30 - 18:14:30 (-)118 ref 15  
Mid SQZ -4cts DHARD PIT 18:15:45- 18:17:45 (-)118 ref 16  
Mid SQZ +4cts DHARD YAW 18:19:30 - 18:21:30 (-)118 ref 17 No difference seen
Mid SQZ SRM YAW 1urad (offset 0.3) 18:28:00 - 18:30:00 (-)120 ref 18 Big difference at 5kHz, none at 10kHz
Mid SQZ SRM YAW -1urad (offset -0.3) 18:33:30 - 18:35:50 (-)114 ref 19 Got better
Mid SQZ SRM YAW -2urad (offset -0.6) 18:41:30 - 18:43:30 (-)108 ref 20 Overshot, got worse, mode didn't flip
Mid SQZ SRM YAW -1.5urad (offset -0.45) 18:46:30 - 18:48:30 (-)108 ref 21  
Mid SQZ 18:52:00 - 18:52:00 (-)118 ref 22 Back to nominal
 
Took OPO setpoint back to 80uW and remeasured NLG to be 22.4. It is interesting that before the SQZT0 pump alignment 86323 we had much worse NLG even with the same OPO trans setpoint and spot on the crystal. This doesn't make sense to us.
OPO Setpoint Amplified Max Amplified Min UnAmp Dark NLG Note
80 0.153078 0.002067 0.0068192 -1.16e-5 22.4 With Optimizing Temp
Images attached to this comment