Displaying report 1-1 of 1.
Reports until 15:29, Thursday 14 August 2025
H1 ISC
elenna.capote@LIGO.ORG - posted 15:29, Thursday 14 August 2025 - last comment - 10:13, Friday 15 August 2025(86370)
Updates to LSC feedforward

I ran a bruco yesterday that showed lots of low-ish broadband coherence of SRCL, PRCL and MICH.

I have a previous good measurement of the PRCL coupling, so I used that to iteratively fit an improved feedforward. Based on the last test I did of the PRCL feedforward, I am not certain that just adjusting the gain is good enough right now to reduce the coupling significantly. screenshot

I also measured and tried to fit a better SRCL feedforward. The challenge continues to be fitting the low and high frequency behaviors of the SRCL coupling simultaneously. The misfit of the high frequency behavior continues to create a broad bump of SRCL noise around 100-300 Hz.

I made some small improvements of the SRCL coupling, but there is still room for more improvement. screenshot

I still need to remeasure and refit the MICH feedforward.

The new SRCL FF is in FM6 and the PRCL FF is in FM8. I updated the guardian and the SDF.

Images attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 10:13, Friday 15 August 2025 (86375)

Follow up bruco taken after these changes shows large reduction in PRCL coherence, some reduction of SRCL coherence. Minimal change in MICH coherence.

Displaying report 1-1 of 1.