elenna.capote@LIGO.ORG - posted 12:14, Monday 18 August 2025 (86423)
Improved MICH feedforward

Continuing work from 86370, I was able to refit the MICH feedforward and get improvement.

The SRCL coupling doesn't seem to be dependent on the SRC ASC offsets that were implemented in this alog, as I checked the coupling today and it was the same as I measured last week (forgot to properly save references before closing DTT so you will just have to take my word for it for now). I was unable to get enough time to measure the high frequnecy SRCL coupling better and refit, so that remains a future task.

Images attached to this report