BS M1 P integrator engaged

I added the BS M1 Pit integrator turning on to the gen_PREP_MICH_ALIGN state of ALIGN_IFO, so that it gets turned on for both initial alignment as well as if we use CHECK_MICH_FRINGES during the full lock acquisition sequence. Hopefully during init align right now after maintenance we'll see that it's working well.

Comments related to this report
elenna.capote@LIGO.ORG - 13:05, Tuesday 19 August 2025 (86451)

TJ and I confirmed that the integrator does now engage during MICH initial alignment! We ran the state twice to be sure.