Reports until 22:00, Tuesday 19 August 2025
LHO General
corey.gray@LIGO.ORG - posted 22:00, Tuesday 19 August 2025 (86465)
Tues EVE Ops Summary

TITLE: 08/19 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Preventive Maintenance
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY:

Shift started out with Elenna & Jenne troubleshooting H1 due to locklosses at DHARD WFS post-Maintenance.  Elenna was eventually able to get H1 past the rough DHARD/CARM Offset steps of ISC_LOCK.  H1 was then able to get back to Observing (please see Elenna's alog for more info---Elenna mentioned, as she was leaving for the night, that this was an issue similar to what she saw after the recent HAM1 vent.).

Violins were elevated on this lock, but once High Power Damping settings were started, most modes were damped down pretty fast.  ETMy M1 was slow, so I helped it out a little (nominal gain is -0.1 for ETMy Mode1, and I have it at -0.2 and will leave it here for the night since it continues to damp this one nicely.
LOG: