Leo, Jennie, Camilla
Followed setup instructions from 80010, with 75mW injected in the SEED beam, we had 1mW on OPO_IR_PD_DC slightly lower than last time. Also took SQZ_FC to FC_MISALIGNED. And opened SQZ beam divertor and fast shutter. Have counts of ~60 on ASC-AS_A and B and 7e-4 on ASC-OMC-A and B NSUMs. Jennie took the OMC PZT down to zero to start and then ran a template userapps/../omc/h1/templates/OMC_scan_sqz_beam.xml.
Repeated mode scans with different ZM PSAMs offsets, the DC centering loops could account for the pitch change for PSAMs, for the extreme PSAMS values, I increased the servo limiter from 85 to 95.
Jennie and Leo have the data to analyze.
See the ndscope with the channels we used to monitor attached.
This template is saved in /ligo/home/jennifer.wright/Documents/OMC_scan/20250819_SQZ_beam_scan_with_ZM_changes.yaml
Leo, Jennie W., Camilla Below is a plot of the OMC scans fitted with a surface polynomial. The plot is from the presentation in T2500228, so the labels on axes will be different. This can be plotted on Matlab simply using the following code block (requires Curve Fitting Toolbox to use fit()). OMCX = [5.5, 4, 2.3, 3, 8.1, 2.3, 2.3, 6, 9.5, 6, 6, 9, 3, 8, 4, 9.5, 9.5]; OMCY = [-0.8, 0.34, 0.2, 0.85, -0.4, -0.1, 0.2, -0.4, -0.6, -4.5, -5.3, 2, 2, -2, -2, -5, -0.6]; OMCdata = [1-4.048/100, 1-3.412/100, 1-3.074/100, 1-3.234/100, 1-5.073/100, ... 1-3.176/100, 1-2.884/100, 1-2.174/100, 1-3.343/100, 1-9.490/100, 1-11.865/100, 1-6.282/100, 1-2.313/100, ... 1-3.013/100, 1-3.021/100, 1-9.179/100, 1-3.243/100]; omc = fit([transpose(OMCX), transpose(OMCY)], transpose(OMCdata), 'poly22'); p = plot(omc);