camilla.compton@LIGO.ORG - posted 09:04, Monday 25 August 2025 - last comment - 11:52, Tuesday 26 August 2025(86543)
Elenna's new SRCL FF Fit turned on

In 86481, Elenna proposed using a new FF fit as the bruco showed SRCL coherence, this has improved the low frequency SRCL noise, but moved the bump at 200Hz to 100Hz, overal a small improvement, see plot attached. Saved in ISC_LOCK and safe and observe sdfs.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 10:25, Monday 25 August 2025 (86549)

I doubled the amplitude of the injection from 0.04 to 0.08, ran the template and saved as /lsc/h1/scripts/feedforward/SRCL_excitation.xml while FM5 was on, so that in the future we can try to fit a separate >100Hz filter as Elenna suggests in 86481. I didn't measure the pre-shaping as expect we recently have that.

Images attached to this comment
elenna.capote@LIGO.ORG - 11:52, Tuesday 26 August 2025 (86572)

In preparation to create a high frequency SRCL FF based on this data, I copied the SRCLFF1 FM10 highpass into FM10 of SRCLFF2 (not to be confused with a different, older "highpass" in FM1 of SRCLFF2).