I have updated the blend filters used for the SR3 P estimator to add in the osem damping for the P peaks at 0.6 and 0.7. The filters I installed were the ones Brian made last Thursday, pit_v2. The filters were installed into the filter banks SUS-SR3_M1_EST_P_FUSION_MEAS_BP and SUS-SR3_M1_EST_P_FUSION_MODL_BP with the OSEM and model blend filters, respectively. They were placed in FM2, and I swapped over from FM1 to FM2 for both of them. These changes were updated in Observe and Safe sdf.
We turned the estimator on with these new filters at 2025-08-25 15:42UTC.