H1 SUS PR3 Pitch and Yaw Estimator: Installed and Run for 1 hour
J. Kissel, E. Bonilla

Thanks to the hard and quick work of the Stanford team overnight designing blend filters and super sensor model filters (LHO:86563), I was able to install everything needed to get the H1SUSPR3's estimator up, running, and functional this morning. After having run it for bit during maintenance (and thus corner-station sensor correction was off), I've turned the "use OSEMs or use Estimator" switch to "use OSEMs" such that the SUS is performing in a functionally equivalent way as "no estimator." We'll run like this until (a) I make some plots analyzing the performance and (b) Until Thursday's commissioning period when we're in nominal low noise, so we can do similar ON vs. OFF comparisons with ASC as our metric.

The P and Y estimators were ON from 2025-08-26 18:05 UTC to 19:00 UTC.

Some extra design points beyond whats made in LHO:86563, with the mind-set of "can we 'just' copy and paste SR3's filters into PR3?"
In short: No.
In long: 
    The existing OSEM-only damping is different -- all SR3's damping loop's overall EPICs gain is -0.5, where PR3's is -1.0. This is demonstrated by LHO:86554, that means the damped M1 drive to M1 response "damped plant" is different. Namely, on resonance, the loop suppression 1/(1+G), is different because G is different, and thus P/(1+G) is different. This has the effect of shifting the fundamental mode frequencies and changing the residual Q. *That* means two things:
    (1) that the OSEM vs. Estimator blend filters -- which are relatively tight notches around resonances -- in principle, should be different. That being said, depending on the performance we end up getting we could *see* if making the blend filters generically wide enough would work. But, for now, we err on the side of "let's make the blend filters specific" because we have the measurements and the person power.
    (2) The "undamped plant" measurements for the estimator -- which are really "lightly damped" plants with whatever loop suppression is left from the broadband OSEM damping that's still always used; an EPICs gain of -0.1 for SR3 and -0.2 for PR3's damping loop controllers -- are different. So, the filters that are modeling that response -- the Sus. Point drive to M1 response filters and the M1 drive to M1 response filters -- will also necessarily be different. However, the differences are almost entirely resonance shifts and Q changes that are proportional to the differences in 1/(1+G) of the light damping (one with scaled with G = -0.1 and one with G=-0.2). Said differently, so far, only the on-diagonal M1 to M1 transfer functions are proving to be needed, and only the P to P, L to P, and Y to Yaw suspension point to M1 transfer functions are needed, and these are almost identical between PR3 and SR3.

I'll put a comparison of the filters and details of the installation in the comments.
Comments related to this report
jeffrey.kissel@LIGO.ORG - 13:08, Tuesday 26 August 2025 (86580)
Here're the comparison between the PR3 and SR3 Suspension Point to M1 response transfer functions.

These we installed using the scripts
/ligo/svncommon/SusSVN/sus/trunk/HLTS/Common/FilterDesign/Estimator/
    make_PR3_pitch_model.m     rev 12622
    make_PR3_yaw_model.m       rev 12622
which push the filters from the saved .mat files 
/ligo/svncommon/SusSVN/sus/trunk/HLTS/Common/FilterDesign/Estimator/
    fits_H1PR3_P_2025-08-19.mat    rev 12622
    fits_H1PR3_Y_2025-08-19.mat    rev 12619
(Most are at rev 12622 because the file names had differing arrangements of underscores and hyphens, so I cleaned that up before running.)

Notably -- we uncovered the oversight of missing L to P filter install in SR3 (LHO:86567) in enough time to make sure the same oversight didn't happen with PR3.

So -- PR3 has 
   - Pitch Estimator P to P, H1:SUS-PR3_M1_EST_P_FUSION_MODL_SUSP_P_2GAP, comparison plot
   - Pitch Estimator L to P, H1:SUS-PR3_M1_EST_L_FUSION_MODL_SUSP_P_2GAP, comparison plot and 
   - Yaw Estimator Y to Y, H1:SUS-PR3_M1_EST_Y_FUSION_MODL_SUSP_Y_2GAP,  comparison plot.

Images attached to this comment
jeffrey.kissel@LIGO.ORG - 13:09, Tuesday 26 August 2025 (86581)
Here's the comparison between the M1 to M1 drive transfer functions. 

These are also installed with the same run of the scripts
/ligo/svncommon/SusSVN/sus/trunk/HLTS/Common/FilterDesign/Estimator/
    make_PR3_pitch_model.m     rev 12622
    make_PR3_yaw_model.m       rev 12622
which push the filters from the saved .mat files 
/ligo/svncommon/SusSVN/sus/trunk/HLTS/Common/FilterDesign/Estimator/
    fits_H1PR3_P_2025-08-19.mat    rev 12622
    fits_H1PR3_Y_2025-08-19.mat    rev 12619
(Most are at rev 12622 because the file names had differing arrangements of underscores and hyphens, so I cleaned that up before running.)

Images attached to this comment
jeffrey.kissel@LIGO.ORG - 13:37, Tuesday 26 August 2025 (86583)
Here's the comparison between the blend filters.

Because I want to have a bit more conversation about this, I show the comparison in detail for each PIT and YAW, and when showing them all together, I show both zoomed in and out in frequency.

Namely: The pitch super sensor blend filter magnitude tops out at 0.9 rather than the traditional 1.0 for a complimentary blend filter. As Brian briefly mentions in his design aLOG (LHO:86510) this because he is mindful of the phase of the sum of this filter and its compliment. The pitch super sensor blend filter was designed to be 
    (SS Blend) = 1 - (OSEM Blend). 
In his design aLOG, he phrases it as "The low-pass [OSEM Blend] is a zero-pole pair so that it levels off to a transmission of 0.1. This is so the gap between the two [0.64 and 0.75 Hz] resonant peaks [which were designed as separate, single z:p pairs] will be well behaved. [The pairs] will cross at about 180 degrees of phase shift and make a sharp zero [between resonances], and [that] deep zero seemed to be causing numerical issues when Oli was implementing the yaw blends. The flat bottom at 0.1 prevents that."
     
    So, if you force the OSEM blend to bottom out at 0.1, then the super-sensor blend will top out at 1 - 0.1 = 0.9.

    This, in effect, sacrifices 10% loop gain for numerical stability.

    Brian says he's working on a -v3 design that might improve this.
    Honestly, I think it's probably fine from an overall loop gain perspective -- I guess this can be rectified by increasing the estimator control filter by 10%, but even if not, 10% less damping is totally fine.

    If loop or numerical stability demands that we can't increase the overall gain can we augment this design such that *well* above the 0.64 and 0.75 Hz resonances -- can we still roll off the OSEM contribution? Say, multiply the whole -v2 OSEM filter by a high-pass at, 10 Hz (and then adjust the SS blend accordingly to keep things complimentary)?
Images attached to this comment