Today we pushed calibration report 20250823T183838Z, which updates the calibration model after changes to the actuation (ESD bias change) and sensing (SRC alignment offset change).
These are the steps I took (and two mistakes I made):
pydarm report --regen 20250823T183838Z with the ESD bias and drivealign L3 L2L gains updated in the ini file. I checked to make sure the results were sensible. There is a change in the sensing function at low frequency, probably from an L2A2L related change.
pydarm report --regen 20250823T183838Z to get the GDS filters, checked the GDS filters to ensure they looked normalpydarm commit 20250823T183838Z --valid --message 'new calibration push, new ESD bias and SRC ASC offsets'pydarm export --push 20250823T183838Zpydarm upload 20250823T183838Zpydarm gds restart
H1:CAL-CS_DARM_FE_ETMX_L3_DRIVEALIGN_L2L_GAIN had not been updated with the new drivealign gain. Once I updated it, CAL DELTA L then looked correct
The attached plot compares the before and after PCAL broadband to GDS CALIB STRAIN. Tony will post the usual alog about the simulines measurement once it is complete.
Sadly, we lost lock mid-simulines measurement. However, the broadband pcal measurement showed success, so we are happy to keep this calibration and we will (hopefully) get simulines Saturday.
Here is the same plot as above, except with PCAL/GDS instead of GDS/PCAL.
We've had two locks since this push, and it appears the systematic error during thermalization is even lower than it was before. We updated the SRCL offset during thermalization, partially because it reduces the systematic error. It appears we do not need to update the thermalization servo, as the systemic error of the 33 Hz line is 2% or less during thermalization.