OPLEV charge measurements, ETMX, ETMY

I processed the OPLEV charge measurments that Rahul took on the 26th.

The charge on ETMY looks stable and low. The charge on ETMX appears high, the error bars are quite large but even with those each quadrant has increased since the last measurement.

Images attached to this report