With the Monday holiday and no calibration run last Sat, ran a calibration this morning to start of a Wed Commissioning session.
Measurement NOTES:
- Following instructions (link)
- H1 at NLN for for ~18hrs (had recent SQZ issue however)
- Calibration_Monitor medm screenshot is attached
- 1500 utc Out of Observing for CALIBRATION
- Broadband measurement started at 1500 utc ended 1505utc
- Measurement at: /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20250903T150035Z.xml
- Simullines measurement
- gps START time: 1440947220 (1506utc)
- gps STOP time: 1440948616 (1529utc)
- File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20250903T150641Z.hdf5
- File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20250903T150641Z.hdf5
- File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20250903T150641Z.hdf5
- File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20250903T150641Z.hdf5
- File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20250903T150641Z.hdf5
- 1530utc ISC_LOCK taken back to NLN & started commissioning