Reports until 15:57, Wednesday 03 September 2025
H1 SEI (OpsInfo, PEM, SEI)
corey.gray@LIGO.ORG - posted 15:57, Wednesday 03 September 2025 (86719)
Riding Through A Magnitude 6.0 Aleutian Islands EQ !!

(Elenna C [in spirit], Ibrahim A, Corey G, Tony S, Jim W)

Summary:  H1 survived a magnitude 6.0 EQ in Alaska via new ASC High Gain button/state.  This preserved a 24+hr lock.  This probably saved us (at minimum 2.5hrs of downtime!):  (1) ~90 min for the earthquake seismic noise to die down & (2) for 1-2hrs of locking.  L1 went DOWN due to this EQ about 20min after we saw it rolling through LHO!

Had my first experience getting to ENGAGE the new RED "ASC Hi Gn" button (see Elenna's alog) for an earthquake!  This tool is still fairly new and "manual" (& cool!) for operators.  Main items for engaging at this point (for me, as a newbie) was waiting for SEI_ENV to go to EARTHQUAKE mode and also watched for any colors on the Picket Fence.  While we were dealing with this earthquake, Jim walked in to also observe and answer questions for us; Ibrahim also gave advice since he's engaged this EQ mode twice.  All the details for what happened are logged below.

How Everything Went "Down"!

2102 VerbalAlarm:  "EQ alert for M6.0 in Aleutians"  (it said "Incoming earthquake from Canada")

Images attached to this report