Reports until 10:07, Friday 05 September 2025
H1 SEI
ryan.crouch@LIGO.ORG - posted 10:07, Friday 05 September 2025 - last comment - 16:27, Friday 05 September 2025(86751)
SEI ground seismometer mass position check - Monthly (#26629)

Last checked in alog86131, Closes FAMIS26629

T240
2025-09-05 10:00:43.259660
There are 13 T240 proof masses out of range (> 0.3 [V])!:


ETMX T240 2 DOF X/U = -1.516 [V]
ETMX T240 2 DOF Y/V = -1.399 [V]
ETMX T240 2 DOF Z/W = -1.032 [V]
ITMX T240 1 DOF X/U = -2.131 [V]
ITMX T240 1 DOF Z/W = 0.423 [V]
ITMX T240 3 DOF X/U = -2.257 [V]
ITMY T240 3 DOF X/U = -1.041 [V]
ITMY T240 3 DOF Z/W = -2.686 [V]
BS T240 1 DOF Y/V = -0.376 [V]
BS T240 3 DOF Y/V = -0.302 [V]
BS T240 3 DOF Z/W = -0.461 [V]
HAM8 1 DOF Y/V = -0.546 [V]
HAM8 1 DOF Z/W = -0.881 [V]


All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = -0.118 [V]
ETMX T240 1 DOF Y/V = -0.145 [V]
ETMX T240 1 DOF Z/W = -0.177 [V]
ETMX T240 3 DOF X/U = -0.113 [V]
ETMX T240 3 DOF Y/V = -0.182 [V]
ETMX T240 3 DOF Z/W = -0.132 [V]
ETMY T240 1 DOF X/U = -0.028 [V]
ETMY T240 1 DOF Y/V = 0.119 [V]
ETMY T240 1 DOF Z/W = 0.164 [V]
ETMY T240 2 DOF X/U = -0.114 [V]
ETMY T240 2 DOF Y/V = 0.163 [V]
ETMY T240 2 DOF Z/W = 0.005 [V]
ETMY T240 3 DOF X/U = 0.172 [V]
ETMY T240 3 DOF Y/V = -0.009 [V]
ETMY T240 3 DOF Z/W = 0.082 [V]
ITMX T240 1 DOF Y/V = 0.214 [V]
ITMX T240 2 DOF X/U = 0.131 [V]
ITMX T240 2 DOF Y/V = 0.223 [V]
ITMX T240 2 DOF Z/W = 0.183 [V]
ITMX T240 3 DOF Y/V = 0.074 [V]
ITMX T240 3 DOF Z/W = 0.094 [V]
ITMY T240 1 DOF X/U = 0.023 [V]
ITMY T240 1 DOF Y/V = 0.082 [V]
ITMY T240 1 DOF Z/W = -0.036 [V]
ITMY T240 2 DOF X/U = 0.017 [V]
ITMY T240 2 DOF Y/V = 0.215 [V]
ITMY T240 2 DOF Z/W = 0.066 [V]
ITMY T240 3 DOF Y/V = 0.029 [V]
BS T240 1 DOF X/U = -0.093 [V]
BS T240 1 DOF Z/W = 0.131 [V]
BS T240 2 DOF X/U = 0.043 [V]
BS T240 2 DOF Y/V = 0.131 [V]
BS T240 2 DOF Z/W = 0.009 [V]
BS T240 3 DOF X/U = -0.194 [V]
HAM8 1 DOF X/U = -0.206 [V]

 

STS

2025-09-05 10:05:11.268277
There are 2 STS proof masses out of range (> 2.0 [V])!:


STS EY DOF X/U = -4.636 [V]
STS EY DOF Z/W = 2.288 [V]


All other proof masses are within range ( < 2.0 [V] ):
STS A DOF X/U = -0.462 [V]
STS A DOF Y/V = -0.819 [V]
STS A DOF Z/W = -0.56 [V]
STS B DOF X/U = 0.186 [V]
STS B DOF Y/V = 0.945 [V]
STS B DOF Z/W = -0.401 [V]
STS C DOF X/U = -0.703 [V]
STS C DOF Y/V = 0.763 [V]
STS C DOF Z/W = 0.543 [V]
STS EX DOF X/U = -0.193 [V]
STS EX DOF Y/V = -0.132 [V]
STS EX DOF Z/W = 0.048 [V]
STS EY DOF Y/V = 1.233 [V]
STS FC DOF X/U = 0.199 [V]
STS FC DOF Y/V = -1.141 [V]
STS FC DOF Z/W = 0.596 [V

Comments related to this report
ryan.crouch@LIGO.ORG - 16:27, Friday 05 September 2025 (86754)OpsInfo, SEI

After seeing that I made mistakes in the past by only running just the T240s or just the STSs, I made a bash script to run them both in their own xterm window, then once they're done all the ouput is printed in the xterm window and copied to the clipboard to be pasted to the alog.

The new button on the WEEKLIES.adl medm is labeled "! STS & T240 Centering"