Reports until 12:17, Monday 08 September 2025
H1 SUS (ISC, SEI)
oli.patane@LIGO.ORG - posted 12:17, Monday 08 September 2025 (86784)
Estimators not causing extra ASC SRC2 Y CTRL noise

In 86589, Jeff points out mysterious noise seen in SRC2 Y CTRL between 1 and 3 Hz that is only seen when the SR3 estimator is fully on with the L to P contribution included.

To verify this, I plotted some other times with the estimators ON and OFF, and looking at those different times, I was able to confirm that the unknown increase in noise Jeff points out between 1 and 3 Hz is NOT caused by the estimator, but by some other noise source in passing.

Images attached to this report