Watchdogs trip following M5.8 EQ off coast of Oregon

SWWDs for ETMY, ITMY and ITMX have tripped.

HWWD for ITMY has just tripped, its RMS is significantly higher than the others.

Strangely ETMX SWWD and HWWD have not come close to tripping.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 21:49, Monday 08 September 2025 (86794)

Ibrahim, Jim, Dave:

SUS RMS have diminished below trip levels. Ibrahim is on his way to the CER to untrip the ITMY HWWD. Jim and I are his remote buddies.

david.barker@LIGO.ORG - 22:09, Monday 08 September 2025 (86796)

To close this out, Ibrahim successfully reset the ITMY HWWD.