Reports until 22:15, Sunday 14 September 2025
LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 22:15, Sunday 14 September 2025 - last comment - 08:25, Monday 15 September 2025(86920)
OPS Eve Shift Summary

TITLE: 09/15 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
INCOMING OPERATOR: None
SHIFT SUMMARY:

IFO is in IDLE for CORRECTIVE MAINTENANCE

The mission today was to get to RESONANCE. We got really close!

The idea was that the calculated TR_CARM offset was likey incorrect so we had to step the offset to maintain stability as we went into resonance. So attempts below are all from CARM_TO_5_PICOMETERS.

While sitting in CARM_TO_REFL during handoff, took RF_DARM TF (attached).

I'm stealing Ryan S's format for his IFO troubleshooting today since it was so easy to read! (Thanks Ryan!)

Reference for healthy CARM to RESONANCE transition pre-outage: 2025/09/09 20:01 UTC, GPS: 1441483301

Relocked,

Relocked,

Ran Initial Alignment - fully auto

Relocked,

Relocked,

Plan now was to try to step the TR_CARM_GAIN up as we were stepping the TR_CARM_OFFSET down further from -52 to keep the UGF consistent and not cause a LL. Sheila plannd to measure this each time we stepped it.

Relocked,

IFO in IDLE per Sheila's Instruction. We will try again tomorrow.

LOG:

None

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 08:25, Monday 15 September 2025 (86922)

Here are two screenshots to show our last attempt last night.

Second one show the TR_REFL 9 erorr signal as we stepped the TR_CARM offset closer to resonance.  There is some noise in the TR_REFL9 signal, due to alignment fluctuations coupling when we are not on resonance.  As we get closer to resonance by increasing the TR_CARM gain as the optical gain of the side of fringe signal drops, the refl signal gets a little quieter. The offset gets set to zero the error signal right before the handoff, and as you can see the handoff to the error signal works well and the refl 9 signal become quiet once it is in loop.  Looking at the TR_CARM signal after the handoff, you can see that the arm powers fluctate because they are now seeing the noise from refl 9 which is now in loop. 

When the offset is removed, TR_CARM goes to about 58.  All build ups become wobbly when the offset is removed to go to resonance.  This means that something seems wrong with the TR REFLAIR9 error signal, which could be due to an alignment problem or an issue with the sensor itself.

 

Images attached to this comment