Displaying report 1-1 of 1.
Reports until 17:07, Monday 15 September 2025
LHO General
ryan.short@LIGO.ORG - posted 17:07, Monday 15 September 2025 (86945)
Ops Day Shift Summary

TITLE: 09/15 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: More progress today towards recovering H1 back to low noise! We've been able to make it up to LASER_NOISE_SUPPRESSION once so far and updated alignment offsets. Unfortunately we did see the slow increase of IMC REFL again once increasing the input power to 63W during LNS, and shortly after there was an IMC-looking lockloss. Since then, Jason and Keita inspected optics in the PSL and didn't find anything alarming. We attempted to reproduce the IMC REFL behavior with just the IMC locked up to 63W with the ISS secondloop on and off, but did not see it, interestingly. We then decided to try locking again, so an initial alignment with the new green offsets is ongoing.
LOG:

Start Time System Name Location Lazer_Haz Task Time End
15:47 FAC Nellie MY N Technical cleaning 16:40
16:40 FAC Kim MX N Technical cleaning 17:31
16:41 FAC Randy MY N   18:25
16:44 ISC Elenna LVEA N Plugging in freq injection cable 16:49
17:49 FAC Kim H2 N Technical cleaning 18:00
21:15 PEM TJ EY N Checking DM vacuum pump 22:13
21:16 PSL Jason, Keita PSL Encl Local Optics inspection 23:11
21:25 VAC Gerardo LVEA N Check HAM6 pump 21:33
21:37 VAC Gerardo MX N Inspect insulation 23:12
21:40 CDS Erik, Fil LVEA/CER N Checking RF chassis 22:13
Displaying report 1-1 of 1.