sheila.dwyer@LIGO.ORG - posted 16:24, Tuesday 16 September 2025 (86974)
added flag to CARM_5_PM for after_power_outage changes

We have been doing some things by hand to lock recently.  I've put a flag in CARM_5_PM to do these. 

This will take the TR_CARM offset to -52 (instead of the caclulated offset), waits, then increases the TR_CARM to 2.1, then sets the offset to -56, increases the DHARD P gain to -30 and Y to -40, and increases the input matrix element for REFLAIR 27 I to PRCL by a factor of 1.6. 

Of these things, I think that the DHARD gain increases should probably be a good thing that we would want to keep in the long run.  The PRCL gain we plan to check early in the locking sequence. 