Displaying report 1-1 of 1.
Reports until 08:04, Wednesday 17 September 2025
H1 General
anthony.sanchez@LIGO.ORG - posted 08:04, Wednesday 17 September 2025 - last comment - 08:56, Wednesday 17 September 2025(86981)
Wednesday Ops Day shift report.

TITLE: 09/17 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 154Mpc
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 2mph Gusts, 1mph 3min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.17 μm/s
QUICK SUMMARY:

H1 is locked and Observering for 12 hours.
The Violins are very upset, seems like EMTY mode 1 is angry.  DCPDS are very diverged.
Main DARM screen is being restarted.


A new Diag_Main:
SEI_STATE: SEI_CONF might be stuck

Comments related to this report
ryan.crouch@LIGO.ORG - 08:56, Wednesday 17 September 2025 (86984)SUS

15:30 UTC I put the nominal gain of -0.1 into ETMY mode1 and it started to damp down.

Iit looked like it was damping at the beginning of the lock with a negative gain, but at 03:44 UTC the gain was changed from -0.2 to +0.2 without pausing at zero which is the safe thing to do. The mode pretty much immediately started to ring up until guardian turned it off at 04:38 UTC. It was damping with nominal at the start of the lock but it was increased in a few steps from -0.1 to -0.4, ETMY mode1 is a finicky mode, increasing the gain does not always increase the damping rate.

Images attached to this comment
Displaying report 1-1 of 1.