1st Calibration sweep since the Power Outage

Calibration sweep ran at 8:30 Local 15:30 UTC
pydarm measure --run-headless bb

.....
...[computer noises]...
....

2025-09-18 08:37:08,412 bb measurement complete.
2025-09-18 08:37:08,413 bb output: /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20250918T153158Z.xml
2025-09-18 08:37:08,413 all measurements complete.


gpstime;python /ligo/groups/cal/src/simulines/simulines/simuLines.py -i /ligo/groups/cal/H1/simulines_settings/newDARM_20231221/settings_h1_20250212.ini;gpstime
PDT: 2025-09-18 08:39:17.330118 PDT
UTC: 2025-09-18 15:39:17.330118 UTC
GPS: 1442245175.330118
...
..... [more computing noises] ....
...
2025-09-18 16:02:03,289 | INFO | Finished gathering data. Data ends at 1442246540.0
2025-09-18 16:02:03,505 | INFO | It is SAFE TO RETURN TO OBSERVING now, whilst data is processed.
2025-09-18 16:02:03,505 | INFO | Commencing data processing.
2025-09-18 16:02:03,505 | INFO | Ending lockloss monitor. This is either due to having completed the measurement, and this functionality being terminated; or because the whole process was aborted.
2025-09-18 16:02:39,467 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20250918T153918Z.hdf5
2025-09-18 16:02:39,474 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20250918T153918Z.hdf5
2025-09-18 16:02:39,477 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20250918T153918Z.hdf5
2025-09-18 16:02:39,481 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20250918T153918Z.hdf5
2025-09-18 16:02:39,485 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20250918T153918Z.hdf5
PDT: 2025-09-18 09:02:39.614492 PDT
UTC: 2025-09-18 16:02:39.614492 UTC
GPS: 1442246577.614492


pydarm report --skip-gds 
...
.... [Final Computer Noises] ....
...

2025-09-18 09:08:18,990 report generation complete.
2025-09-18 09:08:18,990 report file: /ligo/groups/cal/H1/reports/20250918T153918Z/H1_calibration_report_20250918T153918Z.pdf
2025-09-18 09:08:18,990 displaying report /ligo/groups/cal/H1/reports/20250918T153918Z/H1_calibration_report_20250918T153918Z.pdf...

Images attached to this report
Non-image files attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 14:49, Thursday 18 September 2025 (87007)SUS

It looks like the ini file generated in this report has the old ETMX ESD bias actuation values, so I updated it and regenerated the report.

The L3 actuation strength is different by nearly 2% compared to the 8/23 report. This is possibly due to charging. Tagging sus.

Non-image files attached to this comment