Closes FAMIS#26662, last checked 86750 Laser Status: NPRO output power is 1.873W AMP1 output power is 69.91W AMP2 output power is 138.9W NPRO watchdog is GREEN AMP1 watchdog is GREEN AMP2 watchdog is GREEN PDWD watchdog is GREEN PMC: It has been locked 3 days, 3 hr 49 minutes Reflected power = 24.56W Transmitted power = 104.1W PowerSum = 128.7W FSS: It has been locked for 0 days 3 hr and 22 min TPD[V] = 0.5336V ISS: The diffracted power is around 4.5% Last saturation event was 0 days 5 hours and 44 minutes ago Possible Issues: PMC reflected power is high FSS TPD is low
In regards to the "FSS TPD is low" warning, this is simply because we've recalibrated that PD as of Tuesday (alog86972), so the nominal "good" value has changed and I forgot to update this status script accordingly. Since we just realigned the FSS path and are happy with the results, this TPD reading of about 0.54 V is acceptable.
PMC REFL being high is not a new issue, but it doesn't hurt to be reminded about it.