Displaying report 1-1 of 1.
Reports until 12:12, Saturday 20 September 2025
H1 CAL
oli.patane@LIGO.ORG - posted 12:12, Saturday 20 September 2025 - last comment - 09:14, Monday 22 September 2025(87038)
Calibration Measurement September 20, 2025

At the time of starting the calibration suite, we had been locked for 8.5 hours and so were fully thermalized.

Calibration monitor screen

Report (found at /ligo/groups/cal/H1/reports/20250920T183850Z/H1_calibration_report_20250920T183850Z.pdf

Broadband
2025-09-20 18:32:12 - 18:37:23 UTC
/ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20250920T183212Z.xml

Simulines
2025-09-20 18:38:50 - 19:02:14 UTC
/ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20250920T183850Z.hdf5
/ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20250920T183850Z.hdf5
/ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20250920T183850Z.hdf5
/ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20250920T183850Z.hdf5
/ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20250920T183850Z.hdf5

Images attached to this report
Non-image files attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 09:14, Monday 22 September 2025 (87057)CAL, SUS

Adding a comment here to note two things:

The thermalization adjustment of the SRCL offset appears to still be performing well according to the grafana page.

There is a 2% difference in TST actuation strength between the model that was pushed on 8/23 to the model created from this measurement. This is also reflected in kappa TST being about 1.02 after thermalization. This is likely due to charging. Tagging CAL and SUS.

Displaying report 1-1 of 1.