H1 PSL
ryan.crouch@LIGO.ORG - posted 08:05, Friday 26 September 2025 (87110)
PSL Status Report Weekly FAMIS 26663

Closes FAMIS26663, last checked in alog87026


Laser Status:
    NPRO output power is 1.858W
    AMP1 output power is 70.03W
    AMP2 output power is 139.0W
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 2 days, 20 hr 56 minutes
    Reflected power = 24.91W
    Transmitted power = 104.2W
    PowerSum = 129.2W

FSS:
    It has been locked for 0 days 2 hr and 13 min
    TPD[V] = 0.5372V

ISS:
    The diffracted power is around 4.2%
    Last saturation event was 0 days 2 hours and 13 minutes ago


Possible Issues:
    PMC reflected power is high