Displaying report 1-1 of 1.
Reports until 04:06, Friday 26 September 2025
LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 04:06, Friday 26 September 2025 (87153)
OPS OWL Shift: Round 2

Got notified again and since I hadn't slept yet, was still logged in with some ideas of what was causing issues.

H1 got stuck at input align and a quick looksy through the alog found this parcel of frustration from TJ's alog 86095. Using the wiki and following this, I found that indeed:

IM's did not quite restore to an aligned state post EQ so I trended back OSEMs and moved sliders:

This worked! 

But as then I couldn't lock SRY, so I moved SRM a bit in order to maximize AS_A centering peaks!

This also worked!

Back to LOCKING