Reports until 14:33, Friday 26 September 2025
H1 SUS (SUS)
ryan.crouch@LIGO.ORG - posted 14:33, Friday 26 September 2025 (87158)
ETMX charge

It seems like the charge on ETMX is increasing as seen by a few different metrics...

Currently the 'ETMX_L3_LOCK_BIAS_OFFSET' we use while locked is +6.05425, the sign is flipped when we are down. Specifically in the PREP_FOR_LOCKING main() fx it's set to -8.9, and it looks to be switching the value as expected.

There's not all that much we can do about this right now, we should keep an eye on it and make sure the values are flipped during maintenance windows (they should be since it's in GRD).

Images attached to this report