HARD loop update: open loop gain measurements, loop adjustments

Here is a summary of some results from the open loop gain measurements of DHARD Y and CHARD Y, and the implementation of a new CHARD P low pass:

DHARD Y

I measured the DHARD Y open loop gain, results shown here. The dark blue trace shows the original measurement, showing 17 degrees of phase margin and gain peaking of 10 dB. Looking at the loop design, there are three different boost filters applied to DHARD Y, compared here. These boosts in combination seem to be destroying all the phase of the loop. I took a measurement with the 0.9 Hz boost disengaged (FM3), which is shown in the green trace. Then, I disengaged the 0.5 Hz boost (FM4) and remeasured, shown in the red trace. This improved the phase margin to 32 degrees. This obviously resulted in less microseismic suppression. I adjusted the 0.5 Hz boost (FM4) and decided we should operate without the boost in FM3. This plot compares the original loop error signal and RMS with all three boosts (gold), the error signal and RMS without FM3 and FM4 boosts (green) and then error signal and RMS with the updated FM4 boost (red). The RMS increased 50% without both boosts on, the improved boost returns the RMS to that value. There is now more phase margin in the loop. Updated in guardian and ASC high gain script, SDFed (1,2).

CHARD Y

I measured the CHARD Y open loop gain, results shown here. The file had an old reference trace from 2023, shown in bluegreen in the reference. The gray trace shows the first measurement I made today of CHARD Y. The gain appeared to be way too low. I raised the gain to match the old reference, which was a gain increase of 6 dB. Here is a comparison of the RMS of CHARD Y from 14 hours ago (bluegreen reference) and now (red live). The microseism level is the same between these two measurements. Overall, this reduces the RMS of the loop, so I think this is a good adjustment. This is updated in the guardian and ASC high gain script, also SDFed.

CHARD P

I implemented a new CHARD P low pass filter to reduce CHARD P coupling that is apparent in coherence measurements (example).

Here is a comparison of the old controller (red) with the new controller (blue). This replaces the lowpass filter in FM8 with the filter in FM9. I also disengaged the old 200 Hz lowpass that was previously in FM10, as it wasn't doing much. SDFs (1,2). Guardian code and ASC high gain script updated.

The coherence of DARM with CHARD P has reduced, as expected, and increased for CHARD Y, also as expected. I have since created a new lowpass for CHARD Y that should reduce the coherence and is ready for testing at the next opportunity (comparison).

Images attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 11:11, Monday 29 September 2025 (87199)

Here is an improved CHARD Y lowpass at 10 Hz. Saved in FM6. The sacrifice is about 7 degrees, my previous measurement showed that there is 37 degrees at the UGF.

I don't see a difference in DARM, but the DARM coherence with CHARD Y has dropped. There is no change in the loop RMS either (comparing two times with similar microseism levels).

I updated the guardian to use this filter, and I also edited the ASC higain script.