Ops Day Shift Start

 TITLE: 09/30 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Earthquake
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
    SEI_ENV state: EARTHQUAKE
    Wind: 17mph Gusts, 14mph 3min avg
    Primary useism: 1.28 μm/s
    Secondary useism: 0.57 μm/s 
QUICK SUMMARY: Lost lock just a bit ago due to a 6.9 earthquake in the Philippines. Maintenance starting a bit earlier because of this. 

Comments related to this report
thomas.shaffer@LIGO.ORG - 07:55, Tuesday 30 September 2025 (87211)SQZ

Looks like the SQZer unlocked at 1216 UTC this morning, relocking again and gettting back into Observing at 1220 UTC.

camilla.compton@LIGO.ORG - 08:22, Tuesday 30 September 2025 (87213)SQZ

Reason for SQZ unlock was PMC PZT getting to the end of it's range at 100V.