Displaying report 1-1 of 1.
Reports until 10:53, Monday 06 October 2025
H1 SUS (OpsInfo)
elenna.capote@LIGO.ORG - posted 10:53, Monday 06 October 2025 (87314)
Roll mode damping notes

Ryan S, Elenna

Today the roll mode was a bit high, and was rung up further during the SFI testing that Sheila and Camilla ran. We have found its best practice to turn the roll mode damping off when these injections are happening.

Once the injections finished, we turned the damping back on, and it seemed like the mode was either not damping or getting slightly worse. We turned the damping off for seven minutes, and saw that the mode clearly rung up much faster. So, we reengaged the damping, and then tried a slightly higher gain of 42 and then 45 and saw that the mode actually did start to come back down.

So, in short, if a gain of 40 is not bringing the mode down fast enough, it seems like we can at least tolerate a gain of 45. I can't remember if this is an SDF or not, but I know it is guardian controlled to be 40. Tagging opsinfo in case this is useful information.

Displaying report 1-1 of 1.