PR3 measurements for L Estimator

Took meausrments on PR3 for the L estimator that we're installing.

Settings:
- ISI in ISOLATED
- SUSPOINT matrix set for PR3
- SUS in ALIGNED
- Estimators off (using regular damping)
- L DAMP gain to 20% (-0.2), P DAMP gain at 20% (-0.2), Y DAMP gain to 100% (-1.0)


Results:
SUSPOINT to M1
/ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/PR3/Common/Data/2025-10-07_1700_H1ISIHAM2_ST1_WhiteNoise_PR3SusPoint_EstL_*_0p02to50Hz.xml r12689
M1 to M1
/ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/PR3/SAGM1/Data/2025-10-07_1800_H1SUSPR3_M1_WhiteNoise_EstL_*_0p02to50Hz.xml r12690