NOTE: For this particular Thurs Calibration, Commissioning work was done first for almost 2-hrs and then this Calibration was run.
Measurement NOTES:
- Following instructions (link)
- H1 at NLN for for ~19+hrs
- Calibration_Monitor medm screenshot is attached
- This Calibration was run after about 2.25hrs of commissioning
- Broadband measurement started at 17:12:31 utc ended 17:18:04utc
- Measurement at: /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20251009T171253Z.xml
- Simullines measurement
- gps START time: 1444065645.179760 (1720utc)
- gps STOP time: 1444067041.828354 (1743utc)
- File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20251009T172027Z.hdf5
- File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20251009T172027Z.hdf5
- File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20251009T172027Z.hdf5
- File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20251009T172027Z.hdf5
- File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20251009T172027Z.hdf5
- utc ISC_LOCK taken back to NLN & started commissioning
- PDF of PYDARM Report is attached also.