Hugh Radkins and Richard M Tested the ETM-X ESC cable. Hugh was kind enough to work inside the chamber while I checked the connection from outside. ON first inspection 3 out of the 5 pins were making contact. Hugh removed the connector then reseated it rocking it back and forth as he inserted it. This seemed to work. He then tightened the connection alternating between screws until the unit was tight. I retested all of the pins and we have connection through the system.