SRM watchdog trip thresholds updated

We've recently been having some issues with SRM tripping during initial alignment and during DRMI acquisition, alog87370 for example. After consulting with Jeff K, I've bumped up the trip thresholds as listed below. This was based off of the last few trips, so hopefully it has enough of a buffer now. Saved in the safe and observe sdfs.

  Old New
M1 150 250
M2 200 350
M3 225 400

 

Images attached to this report