OPS Thursday day shift summary

TITLE: 10/16 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 151Mpc
INCOMING OPERATOR: Oli
SHIFT SUMMARY: The DARM fom struggled this morning as it wasn't getting data from GDS and sometimes nds2, ETMY beam spot adjustment alog87508, and we had to swap the ITMY L2 sat amp box alog87515. A PRM filter was also turned off alog87523, and I accepted some CDS calibration report related SDFs. After we relocked post sat amp swap there was a 1Hz ringup seen in ASC, but it calmed down.
LOG:

Start Time System Name Location Lazer_Haz Task Time End
15:01 FAC Randy Yarm beam tube N Beam tube inspection, mid to corner 17:56
15:04 FAC Kim , Nellie VAC prep lab N Tech clean 15:31
18:19 ISC Jennie Vac Prep lab N Looks for parts 19:30
18:23 FAC Kim, Nellie Receiving, then Mids N Tech clean and look for stuff 18:49
18:25 PSL Keita Optics lab N ISS array, Laser Safe 19:43
18:32 PSL Rahul Optics lab N Join Keita 19:43
19:04 FAC Eric Staging N Move boom lift to LeXi 19:29
20:06 EE Fil LVEA N ITMY L2 sat amp swap 20:16
20:39 FAC Randy Xarm N Beamtube calking 22:10
21:06 PSL Jennie Optics lab, Vac prep N Check for parts/tools/cleanliness, Laser Safe 22:00
21:34 SUS Rahul LVEA, near PSL N Grab parts 21:47
21:45 PSL Keita Optics lab N ISS array work 23:09
Images attached to this report