Broadband:
Start: 2025-10-16 18:01:42 UTC
Stop: 2025-10-16 18:06:53 UTC
Files: /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20251016T180142Z.xml
Simulines:
Start: 2025-10-16 18:08:33 UTC // 1444673331.797786 GPS
Stop: 2025-10-16 18:31:47 UTC // 1444674725.604456 GPS
Files:
2025-10-16 18:31:47,448 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20251016T180834Z.hdf5
2025-10-16 18:31:47,456 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20251016T180834Z.hdf5
2025-10-16 18:31:47,461 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20251016T180834Z.hdf5
2025-10-16 18:31:47,466 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20251016T180834Z.hdf5
2025-10-16 18:31:47,471 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20251016T180834Z.hdf5
Once again, it pulled the wrong report, regenerated.
I regenerated again after changing "prospring" to FALSE. This report includes GDS filters because we are going to push.
I ran a second PCAL broadband.
Start: 2025-10-16 19:20:36 UTC
Stop: 2025-10-16 19:25:46 UTC
File: /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20251016T192036Z.xml