Displaying report 1-1 of 1.
Reports until 12:13, Saturday 18 October 2025
H1 CAL (CAL)
ibrahim.abouelfettouh@LIGO.ORG - posted 12:13, Saturday 18 October 2025 - last comment - 11:43, Tuesday 21 October 2025(87553)
Calibration Sweep 10/18

Saturday standard coordinated calibration sweep

BB Start: 1444847709

BB End: 1444848020

Simulines Start: 1444848233

Simulines End: 1444849630

2025-10-18 19:06:16,282 | INFO | Finished gathering data. Data ends at 1444849593.0
2025-10-18 19:06:16,498 | INFO | It is SAFE TO RETURN TO OBSERVING now, whilst data is processed.
2025-10-18 19:06:16,498 | INFO | Commencing data processing.
2025-10-18 19:06:16,498 | INFO | Ending lockloss monitor. This is either due to having completed the measurement, and this functionality being terminated; or because the whole process was aborted.
2025-10-18 19:06:52,301 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20251018T184336Z.hdf5
2025-10-18 19:06:52,309 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20251018T184336Z.hdf5
2025-10-18 19:06:52,314 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20251018T184336Z.hdf5
2025-10-18 19:06:52,319 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20251018T184336Z.hdf5
2025-10-18 19:06:52,324 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20251018T184336Z.hdf5
PDT: 2025-10-18 12:06:52.452839 PDT
UTC: 2025-10-18 19:06:52.452839 UTC
 

CALIBMONITOR attached (took screenshot after requesting NLN_CAL_MEAS - might be a mistake but do not know)

Images attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 11:43, Tuesday 21 October 2025 (87609)

I generated the pydarm report from this measurement. I ended up changing "pro-spring" to False and regenerating.

Non-image files attached to this comment
Displaying report 1-1 of 1.