thomas.shaffer@LIGO.ORG - posted 10:57, Monday 20 October 2025 - last comment - 11:17, Monday 20 October 2025(87582)
CSOFT P and INP P gains changed to help avoid 1Hz ringup

Following the success of Ryan Short's lock with these new gains (alog87573), we updated lscparams.py with CSOFT P = 30 and INP P = -2.

We reloaded all nodes that use lscparams.py, and checked Dave's GRD CFC screen to see the affected nodes. 

Comments related to this report
thomas.shaffer@LIGO.ORG - 11:17, Monday 20 October 2025 (87584)

INP P gain accepted in SDF. CSOFT doesn't look to be monitored.