Reports until 12:47, Tuesday 21 October 2025
H1 SUS (SUS)
edgard.bonilla@LIGO.ORG - posted 12:47, Tuesday 21 October 2025 (87613)
SR3 OSEM estimator blends updated for L/P

We built on the templates set by the PR3 L/P estimator blends [see LHO: 87596] to create Length and Pitch blend filters for the SR3 OSEM estimator.

The functions that make the model and OSEM filters live in:
       blend_SR3_lengthv2_LP_est.m
       blend_SR3_pitchv2_LP_est.m

The files were committed to the SVN at (svnRoot)/sus/trunk/HLTS/Common/FilterDesign/Estimator/ under revision 12741.

make_EST_blends.m in the same folder should work for getting these onto the real-time model.

Images attached to this report