Reports until 16:31, Thursday 30 October 2025
LHO General
thomas.shaffer@LIGO.ORG - posted 16:31, Thursday 30 October 2025 (87849)
Ops Day Shift End

TITLE: 10/30 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
INCOMING OPERATOR: Oli
SHIFT SUMMARY: 3 lock losses during my shift today, the first two looked vaguely similar, but we haven't come to any conclusion as to what the cause was. The last one was due to a ADC card failure at SEI EY. During troubleshooting of this the interlocked was tripped and we had to recover all of the site lasers after the ADC card was fixed. We ran an initial alignment and we are now back to NLN. For both of the relocks in the morning the 1Hz ringup didn't show up, but we just saw it come up for this lock. Oli pressed the new high ASC button.
LOG:

Start Time System Name Location Lazer_Haz Task Time End
14:43 FAC Randy Xarm n BTE sealing, starting at EX 18:43
15:32 PEM Robert LVEA n Measurement setup 17:32
16:01 IO Rahul Opt Lab LOCAL JAC optics 17:56
20:25 CDS Dave, Fil EY n h1iopseiey troubleshoot 21:42
21:07 - Jeff S Arms n Running arms 22:09
21:11 FAC Tyler & APEX contractor Mid Y N Contractors doing work in Mid Y 23:11
21:22 Safe T Danny Mid X N Inspecting Harnesses 23:22
21:24 - Oli, Tony LVEA n Turning lasers back on 21:44
21:25 - Fil EX n Turning on ALS laser 21:45
22:01 IO Keita Opt Lab LOCAL JAC optics 22:38