J. Kissel, D. Barker After consulting with Dave this morning, and him snooping around a bit, it turns out the compilation failure of the h1sushtts.mdl (see LHO aLOG 8777) was just a stupid mistake of an extra carriage return under the OM3 block. Sheesh. The new HTTS front-end model, ${userapps}/release/sus/h1/models/h1sushtts.mdl now compiles just fine. In addition I've moved on to and finished the same upgrade to the HAUX front-end model, ${userapps}/release/sus/h1/models/h1susim.mdl I'll reinstall, restart, and restore tomorrow during maintenance and then begin the process of updating the MEDM screens with the hopes to be done by the end of the day. That will FINALLY close out the modifications to ALL SUS from ECR E1300578.