Reports until 13:41, Tuesday 04 November 2025
H1 SUS
oli.patane@LIGO.ORG - posted 13:41, Tuesday 04 November 2025 - last comment - 16:00, Tuesday 11 November 2025(87950)
Most of the rest of the measurements for H1SUSPRM for Estimator

Last week (87801) Jeff took a bunch of transfer function measurements for PRM for the PRM L, P, and Y estimators. There were some he wasn't able to take:

- H1ISIHAM2 to H1SUSPRM M1 for all dofs with DAMP L, P, and Y all with 20% gain

- H1ISIHAM2 to H1SUSPRM M1 for all dofs with DAMP Y at 20% gain

- H1SUSPRM M1 to M1 for V, R, P, Y with DAMP Y at 20% gain

Today I was able to get the first two bullet points done

Measurements:

First, I made sure the SUSPOINT matrix had the correct values for driving PRM, which it did. 

First set (L P Y DAMP gain at 20%):

L, P and Y DAMP gains were set to 20% of their nominal values, so they were set to -0.1, and T, V, and R were left at their nominal -0.5 gain values. 

Measurements can be found in 

/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/Common/Data/2025-11-04_1800_H1ISIHAM2_ST1_PRMSusPoint_M1LPYDampingGain0p1_WhiteNoise_*_0p02to50Hz.xml r12766

Second set (Y DAMP gain at 20%):

After those measurements were taken, I set the L and P DAMP gains back to their nominal values of -0.5 and took another set of SUSPOINT measurements with only the Y gain at 20%.

Those measurements can be found in 

/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/Common/Data/2025-11-04_1930_H1ISIHAM2_ST1_PRMSusPoint_M1YawDampingGain0p1_WhiteNoise_*_0p02to50Hz.xml r12767

I ran out of time and wasn't able to finish the four M1 to M1 dofs that were left for the reduced Y damping, so we'll have to get those next week.

I also wasn't able to get in any measurements for SRM, but that's okay since we're not in a rush.

Comments related to this report
oli.patane@LIGO.ORG - 16:00, Tuesday 11 November 2025 (88067)

complete PRM measurements: 88063