moving LOWNOISE_ASC to just before NLN with a 5min timer

M. Todd, S. Dwyer, T. Shaffer


After the 1Hz ring up causing a lockloss we decided to move LOWNOISE_ASC to just before NLN and gave it a 5min timer before it goes and sets gains. This should hopefully give the IFO enough time to thermalize past MAX_POWER and keep the higher gains in the ASC loops until the 1Hz oscillation comes back down.

Comments related to this report
thomas.shaffer@LIGO.ORG - 10:59, Thursday 06 November 2025 (87991)OpsInfo
matthewrichard.todd@LIGO.ORG - 12:46, Thursday 06 November 2025 (87992)

Jenne noticed the ADS lines were in NLN now because I moved LOWNOISE_ASC but did not take into account the ASC_ADS lines gain, which should not be turned on. Commented the "turning on" out in the guardian code.