J. Kissel, D. Barker There was a significant amount of extra work installing the new HAUX and HTTS models on their respective front ends, so I detail below. ${userapps}/sus/${ifo}/models/${ifo}sushtts.mdl ------------------------------------ - Make sure to remove ${ifo}asctt and replace with ${ifo}sushtts (or capitalized version, when appropriate) in the following files: - /diskless/root/etc/rtsystab (on boot machine, i.e. ${ifo}boot0) - ${userapps}/release/cds/${ifo}/daqfiles/${ifo}dc0/master (which hopefully is the source of the softlink in /opt/rtcds/${site}/${ifo}/target/${ifo}dc0/) - the framebuilder's .ini file, - the test point manager's .par file, and - the EPICs database's EDCU .ini file - ${userapps}/release/cds/${ifo}/daqfiles/${IFO}EDCU_DAQ.ini - Log onto ${ifo}build front-end - make ${ifo}sushtts - make install-${ifo}sushtts - Log onto ${ifo}asc0 front-end - kill${ifo}asctt (Needs to be removed from front-end kernel, since it'll no longer be used) - start${ifo}sushtts ${userapps}/sus/${ifo}/models/${ifo}susim.mdl (much more simple, more typical since the model already exists) ------------------------------------ - Log onto ${ifo}build - make ${ifo}susim - make install-h1susim - Log onto ${ifo}sushh2b - start${ifo}susim Since there are a ton of new channels, one will need to restart the data-concentrator, - telnet h1dc0 8087 > shutdown And for good measure (because it seemed to be running slowly), we restarted the EPICs gateway, but this isn't necessary. Stay tuned -- a plethora of MEDM screen modifications are next!