Calibration Sweep 11/08

Ran a successful coordinated CAL sweep with LLO. We waited ~1hr after the SE standown so sweep was done ~12:15 PM Local

BB Start: 1446668440

BB End: 1446668752

Simulines Start: 1446668866

Simulines End: 1446670223

2025-11-08 20:50:06,504 | INFO | It is SAFE TO RETURN TO OBSERVING now, whilst data is processed.
2025-11-08 20:50:06,504 | INFO | Commencing data processing.
2025-11-08 20:50:06,504 | INFO | Ending lockloss monitor. This is either due to having completed the measurement, and this functionality being terminated; or because the whole process was aborted.
2025-11-08 20:50:42,733 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20251108T202728Z.hdf5
2025-11-08 20:50:42,741 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20251108T202728Z.hdf5
2025-11-08 20:50:42,746 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20251108T202728Z.hdf5
2025-11-08 20:50:42,751 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20251108T202728Z.hdf5
2025-11-08 20:50:42,756 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20251108T202728Z.hdf5
PST: 2025-11-08 12:50:42.885356 PST
UTC: 2025-11-08 20:50:42.885356 UTC
GPS: 1446670260.885356
 

Images attached to this report