Hugh noticed that some HEPI ITMY slow channels were not correct in the DAQ. I did some investigation and found:
Of the slow channels (datarate=16) in H1ISIITMY.ini :
channels associated with the FEC were correct
channels associated with Filter Modules were correct
other slow channels were incorrect, either showing zero or other data (like channel hopping)
Fast channels appear to be OK (within the limited sample I used)
The problem is not seen with HEPI BS or ETMX. Looking at the models they all look identical.
Reboot/Restarts:
I first restarted h1hpiitmy. Then tried restarting all models on h1seib1. Then tried a restart of the mx-streamers. Then recompiled and reinstalled the h1hpiitmy model and restarted it, followed by a DAQ restart (DAQ status was good, so this should have been unnecessary). All to no avail.
The only thing I haven't done is reboot the computer.
It appears this problem appeared when we upgraded to RCG2.8 on Tue 12 November.