ODC screens updated
During the last suspension model updates, many SUS models started reporting some additional status bits. I did a first round of cleanup of the overview screens to show all bits.
- fixed the number of bits and the mask names in a series of model specific ODC screens.
- ODC overview screen update:  fixed the numer of bits and switched to the _LATCH version of the ODC channel ( this channel latches for 1 sec.)
- set the bit mask for all SUS and SEI models.

Still to do: 
- number of bits for the BS is different than ITMs - it needs it's own BSC screen
- set the string bit label s
- update IMC model
- in collaboration with SEI: the ISI scripts currently incorrectly set he desired state channels.