oli.patane@LIGO.ORG - posted 10:14, Thursday 18 December 2025 (88590)
JM3 and PM1 OSEMINF and WD_OSEMAC_BANDLIM satamp compensation filters updated to compensate for newly swapped satamp

Rahul, Oli

Fil swapped out the JM3 / PM1 satamp this morning (88588) to the modified satamp (modified for ECR E2400330). I used my script python3 sustrunk/Common/PythonTools/satampswap_bestpossible_filterupdate_ECR_E2400330.py -o JM3 PM1 to update the satamp compensation filters in the OSEMINF and WD_OSEMAC_BANDLIM filter banks from 10:0.4 to the precise compensations for each OSEM.

I loaded these filters in and committed thefilter file as r34282.

Note that the satamp swap and the satamp compensation value update will change the perceived location of the OSEM OUTs